Data Centres & Telecom
Precision cooling with concurrent maintainability, free-cooling economisers and monitored power for server rooms, exchanges and towers.

Server halls and telecom exchanges need cooling that is available 99.99% of the time, holds 18–27 °C at the rack inlet and does not waste power moving air. MHM designs chilled-water and DX precision cooling with N+1 or 2N redundancy, hot-aisle containment, economisers for the cooler months and BMS/DCIM integration.
We also supply the generators, LT panels and UPS-room cooling that keep a site up through a grid failure, with breakdown support from our service team.
The engineering problems in data centres & telecom
Concurrent maintainability
N+1 chillers, dual pipe risers and CRAH units so any component can be serviced with the hall live.
PUE and part-load
High chilled-water temperatures, VFD everything and free-cooling in December–February.
Airflow management
Hot-aisle containment, raised-floor or in-row units and rack-inlet sensors on the BMS.
Power continuity
Generator sets, ATS and panel design that restart cooling within seconds of an outage.
How we solve them
- 1
Precision cooling
Chilled-water CRAH or DX CRAC units in N+1/2N with containment.
- 2
Central plant
Air-cooled chillers with buffer tanks for ride-through and economiser coils.
- 3
Power
Generators, LT panels, ATS and UPS-room cooling.
- 4
Monitoring & support
BMS/DCIM integration and breakdown support from our service team.
Services specified for data centres & telecom
HVAC
AHU, FCU, VRF and ducted-split systems for factories, hospitals and offices.
Chillers
MHM-manufactured and imported chillers — air cooled and water cooled, 5–850 TR.
Fire Detection & Protection
Addressable fire detection and alarm, plus hydrant, sprinkler and suppression systems.
Water Treatment Plants & Chemicals
RO, DM, softener and effluent treatment plants, plus treatment chemicals for cooling towers, chillers and boilers.
Power & Electrical
Generators, transformers, UPS and battery banks, switchgear, distribution panels and voltage stabilizers.
Data Centres & Telecom plants running MHM equipment
Common questions from data centres & telecom plants
Below about 50 kW IT load, DX precision units with N+1 are simpler and cheaper. Above that, chilled water with buffer tanks gives better efficiency and ride-through.
Yes — BACnet/IP or Modbus TCP points for every chiller, CRAH, generator and panel are provided with the point list.
Industries we serve
Textile & Garments
Dyeing, finishing, spinning and garment plants: process chilled water for jet dyeing, humidification for spinning, comfort cooling for sewing floors.
Pharmaceuticals
GMP HVAC with validated temperature, humidity and pressure control, purified-water plants and documented service records for audit day.
Steel & Re-rolling
Induction-furnace and mill cooling: closed-loop soft-water circuits, high-capacity cooling towers, plate heat exchangers and pumps that run three shifts.
Food & Beverage
Hygienic process cooling, cold rooms and ice-water systems for edible oil, dairy, beverage, bakery, poultry and seafood plants.
Plastics & Packaging
Mould and extruder cooling, compressed air and clean power for injection moulding, PET, film, pipe and packaging plants.
Commercial Buildings
Central HVAC for malls, hotels, offices and showrooms: chillers, AHUs, VRF, BMS and fire systems that keep tenants comfortable and bills predictable.
Hospitals
Operating-theatre and ward HVAC with pressure control, redundancy and 24-hour support — because a hospital plant is never allowed to stop.
Energy, Gas & CNG
Compressor cooling, LPG and SNG systems, fire protection and standby power for CNG stations, LPG and oil terminals, battery and power plants.
Government & Institutional
Public buildings, defence workshops and institutions: tendered HVAC and utility works delivered to PWD specifications with full documentation.
Planning a data centres & telecom plant or expansion?
Site survey, load calculation and a written proposal are free. We will show you a reference plant like yours.